Excess moisture in or below the concrete slab is the cause for a
large percentage of coating failures on concrete. While moisture
in concrete during the application of floor systems is an important
criterion, it is not the ultimate cause of failure months or years
later. Many resin based flooring systems can tolerate and bond to
a concrete slab with relatively high moisture content. It is the
flow of moisture or moisture vapor, better described as moisture
vapor transmission, which causes most adhesion problems.
Perdüre MVT+ is a moisture vapor control system utilizing a unique
water based epoxy which allows installation of epoxy resin floor
systems and other moisture sensitive floor coverings on new concrete
(5 days old) without fear of moisture entrapment. Perdüre MVT+ is
applied in a two coat application.
Perdüre MVT+ reduces the passage of water vapor and moisture through
slabs on above or below grade, thus eliminating delamination and
blistering of adhesives, floor coverings, resin floor systems, epoxy
terrazzo and coatings. It controls water vapor transmission levels
for the installation of most floor covering systems, including VCT,
sheet vinyl, carpets, wood, laminates, epoxy resin flooring and epoxy
terrazzo.
| TECHNICAL DATA | |
| Density | 12.70lb/gal |
| VOC (mixed) | less than 1g/L |
| Volume of Solids | 59% |
| Flash Point Part A Part B |
greater than 212°F 170°F |
| Mixing ratio | 1:4 by Vol |
| Pot life, approximate | 60 minutes @ 75°F |
| Open to foot traffic | 16 hours at 75°F |
| Curing temperature | At least 50°F |
| Full cure | 7 days |
| Hardness, Shore D | 70-75 |
| Compressive Strength ASTM C579 | 6500psi |
| Flexural strength ASTM C-580 | 2100psi |
| Adhesion to New Concrete (5 days) Moist concrete (28 days) Dry concrete (28 days) |
110psi 550psi 580psi |
Perdüre MVT is a two component modified epoxy system designed to seal concrete and reduce moisture vapor transmission prior to applying finished flooring. Perdüre MVT has proven to reduce moisture vapor emissions and be resistant to damage from high alkalinity. It is an environmentally friendly material containing no hydrocarbons or other solvents making it zero VOC.
Perdüre MVT is designed as a negative side moisture vapor retarder to reduce moisture vapor transmission though concrete.
| TECHNICAL DATA | |
| Tensile Strength ASTM D-638 | 10,400psi |
| Tensile Elongation ASTM D-638 | 2-4% |
| Modulus of Elasticity ASTM D-638 | 2500psi |
| Bond strength to concrete, ASTM D-4541 | 400-500psi100% concrete failure |
| Permeability ASTM E-96 | 1 coat (10-12mil) – 0.09 Perms2 coats (20mil) – 0.04 Perms |
| Water vapor transmission grams/hr/m2 ASTM E-96 | 1 coat – 0.0232 coats – 0.012 |
| Alkali Resistance7 day immersion14 day immersion ASTM D-1308 | 10% NaOH– unaffected50% NaOH- unaffected10% NaOH- unaffected50% NAOH- unaffected |
| Hardness Shore DASTM D-2240 | 85 |
| VOC | Zero |
| Water absorption ASTM D-570 | Zero |
| Mix ratio | 2A : 1B |
| Pot life | 30 minutes |
Recoat
time |
4-6hr 72 hr |
NOTE: It is important to understand the difference between moisture vapor transmission and moisture content. You may have low moisture content and have a bond failure at some point in the future due to vapor transmission through the slab. A high moisture content in the slab will usually not cause a problem unless conditions are right to cause movement of that moisture to the surface. So, its moisture transmission to the surface whether it is from high moisture content in the slab or under the slab that causes the problem.
The maximum moisture vapor transmission through concrete when tested as per the Calcium Chloride Test, should not exceed 3.0lbs/24hr/1000 sq.ft.